back to the stack
Supportedscore 96.6 / 100 · updated 2 days ago

Tower A · Level 1

Handover-ready

How this verdict was computed
BOQ quantity complete99×0.40
MB pages 180–219 · 5 items
Checklist pass rate99×0.20
stage QA checklist register
RA-bill certified97×0.20
RA-06 certified abstract
NCR burden (inverted)88×0.10
4 NCRs on this floor
Schedule slip (inverted)90×0.10
programme baseline rev 4

Weighted score 96.6. Evidence coverage 97%. Two rules sit above this arithmetic: over 8% material variance or an open critical NCR forces Contradicted; under 30% evidence forces Unobserved regardless of how good the numbers look.

BOQ items on this floor
ItemPlannedMeasuredCertifiedVerdict
BOQ 4.2
RCC M25 in slabs, beams & landings incl. shuttering and finishing
514846Supported
BOQ 5.1
Brickwork 230mm thick in CM 1:6 with second class red bricks
646058Supported
BOQ 6.4
12mm cement plaster in CM 1:4 to internal walls
285284273Supported
BOQ 8.3
Vitrified tile flooring 600×600 laid on 20mm CM 1:4 bed
280268257Supported
BOQ 9.1
APP membrane waterproofing to toilets and terrace incl. screed
340328315Supported
Material reconciliation — theoretical vs actual
MaterialTheoreticalActualVarianceAt risk
OPC 53 cement
store issue register · 4 slips
105.66 bag110.63 bag+4.7%₹2,033
TMT Fe550
store issue register · 7 slips
4.27 T4.4 T+3.0%₹7,592
M-sand
store issue register · 8 slips
37.94 T38.62 T+1.8%₹775
20mm aggregate
store issue register · 7 slips
41.31 T43.09 T+4.3%₹1,744
Red brick
store issue register · 8 slips
4,926.3 no5,128.28 no+4.1%₹1,798

Anything above 8% is Contradicted. Cement does not evaporate — it walks out of the gate.

Open non-conformances
Linked documents
Site photographs
IMG-A-01-1
Slab soffit after de-shuttering, east bay
10 Aug 2026 · 09:12
12.9698°N 77.7500°E ±4m
IMG-A-01-2
Blockwork progress, units 03 & 04
11 Aug 2026 · 10:19
12.9698°N 77.7500°E ±5m
IMG-A-01-3
Reinforcement in place prior to pour, zone 2
12 Aug 2026 · 11:26
12.9698°N 77.7500°E ±6m